XIA Luan-bao, WANG Xi-long, LIU Li-shen. STUDY ON THE MISLEADING IN SCALING OF SEISMIC GEOPHONE CONSTANT[J]. North China Earthquake Sciences, 2002, 20(3): 51-55.
Citation: XIA Luan-bao, WANG Xi-long, LIU Li-shen. STUDY ON THE MISLEADING IN SCALING OF SEISMIC GEOPHONE CONSTANT[J]. North China Earthquake Sciences, 2002, 20(3): 51-55.

STUDY ON THE MISLEADING IN SCALING OF SEISMIC GEOPHONE CONSTANT

  • in the scaling of seismic geophone, the air damping will be too large to measure D 10 accurately, thus causing S1, a12, RD, and C all inaccurate.The V we get will be inaccurate also, and the waveform of seismic record will be affected simultaneously.So we suggest we should connect in series a resistance R when scaling.Only if the inputting resistance of amplifier Ri≥10MΩ, the results will meet the need of the criteria.The tests all get good effect in the study.